MIL-L-80061B
3.4.8 Electrical system. Unless otherwise specified (see 6.2.1), the
electrical system shall conform to all requirements in this paragraph.
The system shall conform to the requirements of ANSI/NFPA No. 79. The
machine shall draw all of its electrical power f ran a single 230/460 volt,
3 phase, 60 Hz circuit, The machine shall be initially wired for opera-
tion on 460 volts. An identified terminal for grounding the machine when
installed shall be mounted in or near the disconnect switch.
3.4.9 Motors. Motors shall have ball or roller bearings. Continuous
duty Power ratings shall conform to the requirements of table I. Unless
otherwise specified (see 6.2.1), each motor enclosure shall meet the
requirements for a dripproof enclosure.
3.5 Sizes and capacities. The sizes and capacities of the machine shall
meet the requirements of table I as applicable for the machine type speci-
f ied in the contract or order.
8